Owing to its extremely low thermal conductivity and good thermal stability, silica aerogel has a potential application for the protection of concrete linings, with the aim of delaying the heating of the high performance concrete and extending the performance of the main concrete structure of the tunnel under fire. A recent collaborative study with Empa’s Concrete/Construction Chemistry Lab shows layers of 40-50 mm of the aerogel cement mortars are able to avoid fire spalling of high-performance concrete cubes [1].
1] Zhu, Pinghua, et al. "Study of physical properties and microstructure of aerogel-cement mortars for improving the fire safety of high-performance concrete linings in tunnels." Cement and Concrete Composites 104 (2019): 103414.
Dr. Shanyu Zhao
Group leader in Functional Aerogel Materials Group
Nous utilisons des cookies pour administrer le site, suivre les mouvements des utilisateurs sur le site et collecter des informations démographiques sur notre base d'utilisateurs dans son ensemble. Acceptez tous les cookies pour bénéficier de la meilleure expérience possible sur notre site web ou gérez vos préférences.